ZW32-12 Permanent magnet outdoor vacuum circuit breaker
Release time:2015-06-06 01:35 Read:Time

 
●Overview
ZW32-12 type permanent magnet outdoor vacuum circuit breaker (hereinafter referred to as circuit breaker) for a period of 12 kv, rated voltage of the three-phase ac 50 hz outdoor distribution equipment Is mainly used for open circuit close load current overload current and short circuit current in power system for substation and industrial and mining enterprises for protection and control in power distribution system, and the site of rural power grid frequent operation

This circuit breaker has small volume light weight prevent condensation free maintenance and other characteristics, can adapt to the harsh climate conditions and pollution environment


●Performance advantages

This product USES the permanent magnetism operating mechanism type operation; Because of the permanent magnetic operating mechanism to provide permanent magnet retention, keep the switch in the closing position, the number of mechanical parts Mechanical transmission chain is short, thus greatly improving the reliability and mechanical life of the switch


●Main technical parameters
no. project Unit data
1 Rated voltage KV 12
2 Rated frequency HZ 50
3 Rated current A 630
4 Rated short circuit breaking current KA 20
5 Rated peak withstand current(peak) KA 50
6 rated short time current KA 20
7 Rated peak with stand current(peak) KA 50
8 mechanical life 10000
9 Rated short circuit breaking current open circuit 30
10 power frequency withstand voltage
(1 Min ):Wet(Alternate  \to ground \ Fracture )
KV 42/48
11 Lightning impulse withstand voltage (peak)
(Alternate  \to ground \ Fracture )
KV 75/85
12 The secondary loop power frequency withstand voltage(1 min)
 
KV 2

Outline Mounting Dimension

1. The above outlet
2. blowout coil
3. insulation covering
4. Under outlet
5. the electrical clip
6. braid connection
7. insulating tension pole
8. Contact pressure spring
9.    breaking spring
10. Drive even the plate
11. actuator shaft
14.    Power dry each device
13. mechanism case
 
 


1. operating handle
 4. Open& close instructions
7. Insulator
10. Wiring board (into the terminal)
2. Isolation of the spindle
 5. Connecting plug
8. Dummy carriers
11. The isolation knife method
3. Break-brake handle
6. Current transformer
 9. insulating tension pole
12. Circuit breaker
 
 